What to Know Before Selecting a Mold Temperature Controller

By Moldex3D

In injection molding, the mold usually is controlled at a fixed temperature by making coolant continuously flow through the mold. If the coolant flow is not enough or the coolant temperature is not as expected, the mold temperature won’t be able to stay at the designated temperature. The manufacturers of mold temperature controllers calculate the appropriate mold temperature controller specifications according to the size of the mold and the part. 

However, it can be a challenge for engineers and analysts using the simulation software to evaluate the performance of a mold temperature controller. In this article, principles will be shared for using CAE software to better evaluate the performance of mold temperature controllers.

The relation between flow and pressure in cooling channels

Users of CAE software can apply two types of boundary conditions for cooling channels: flow rate and pressure. When the coolant flows through the cooling channel, the flow rate at the inlet and outlet are equal. Users only have to measure the flow rate at one side of the cooling channel to attain the flow rate at the other side. Thus, using the flow rate as the boundary condition is easier to control. 

relation-chart-of-cooling-channel-flow-rate-and-pressure-difference
Fig. 1 The relation chart of cooling channel fl ow rate and pressure difference

In terms of pressure, the inlet pressure is higher than the outlet pressure, and the flow is caused by this pressure difference. In Moldex3D, the default value of the outlet pressure is zero. Users only set the pressure boundary at the inlet, and this value will be equal to the pressure difference between the inlet and outlet. If a plot is created to show the relationship between the cooling channel flow rate and pressure, it can be seen that the flow rate gets larger as the pressure difference gets larger. The two parameters are approximately proportional (Fig. 1).

darcy-weisbach-equation
Fig. 2 Darcy-Weisbach equation

Apart from the pressure difference, flow resistance is another factor that will affect flow. Flow resistance varies with some conditions, such as cooling channel diameters, channel length, channel wall smoothness, coolant properties and flow rate. The Darcy-Weisbach equation shows the relation between these parameters (Fig. 2).

The relation between flow rate and pressure of mold temperature controllers

The function of a mold temperature controller is to push the coolant to flow and stabilize the coolant temperature. The main function of the pump in the mold temperature controller is to push the coolant to flow. When the pump pressure rises, the flow rate decreases; when the flow rate increases, the pump pressure decreases. The maximum flow rate and maximum pressure values on the mold temperature controller specification can be seen, but the two conditions never exist simultaneously. 

Choosing the right mold temperature controller

Users can obtain the flow rate and pressure difference of every cooling channel through cooling channel analysis. The total flow rate of the cooling channels is the flow the mold temperature controller must provide. The maximum pressure in the cooling channel is the minimum pressure the mold temperature controller must provide. 

loadable-area-of-the-mold-temperature-controller
Fig. 3 The loadable area of the mold temperature controller

Users can enter point coordinates of the total flow rate and maximum pressure differences in the line graph. If the coordinate point is below the line, it means the mold temperature controller can provide enough flow rate and pressure. If the coordinate point is above the line, it means the mold temperature controller cannot provide enough flow rate and pressure (Fig. 3). 

Before running a simulation

In the injection molding simulation, users usually set high flow rate as the ideal cooling channel condition. However, users will get a large value after converting it to meet the requirements of the mold temperature controller. Therefore, in order to shorten the gap between simulation and reality, it is better to set the channel boundary conditions based on the actual specifications of the temperature controller unit. 

In addition to flow pressure, it also is necessary to take the cooling and heating capabilities of the mold temperature controller into consideration in simulation. Users can check the heating load of the cooling channels and compare the values with the cooling and heating capabilities. If the cooling capability of the temperature controller exceeds the requirement of the predicted heating load of the cooling channel or its heating capability exceeds the requirement of the negative heating load of the cooling channel, that means the mold temperature controller meets the requirement. 

Simulation technology can provide critical data to help evaluate mold temperature controllers, and it can help greatly in evaluating a mold temperature controller in reality.

Moldex3D is a world-leading CAE product for the plastic injection molding industry. The software assists with simulation of a wide application range of injection molding processes to optimize product design and manufacturability, shorten time-to-market and maximize ROI. The latest version of Moldex3D, R17, was introduced at the K Show and now can provide the data of maximum pressure drop, total flow rate and heat dissipation to assist with the evaluation of mold temperature controller performance. For more information, visit www.moldex3D.com.